All Strands are lubricated with V1000 environmentally friendly wireline inhibitor. Strands are packed layer by layer wound on strong wooden reels in unbroken lengths.
Conventional Strands - Construction 1x16(6/9/1) - Left Hand Lay
Wire Characteristics
|
Diameter
|
Flow Tube Bore*
|
Min. Pulley Diameter Inches**
|
Weight Lbs/ 1000ft Conventional
|
|
3/16”
|
0.196
|
12
|
70
|
|
7/32”
|
0.228
|
14
|
100
|
|
1/ 4”
|
0.263
|
16
|
130
|
|
5/16”
|
0.33
|
20
|
196
|
General Information
*Flow Tube Bore - the off tension diameter will be stated on the works test certificate. It is recommended that note be taken of this when first using the strand.
*Minimum Pulley Diameter - the figures shown above are our recommendations for reasonable fatigue life. The breaking loads being used should also be considered.
Nominal Breaking Loads
|
Diameter
|
Galvanised
|
316
|
GD31MO
|
|
3/16”
|
4960
|
3990
|
4400
|
|
7/32”
|
6610
|
5400
|
5960
|
|
1/ 4”
|
8640
|
7030
|
7750
|
|
5/16”
|
13490
|
11000
|
12110
|
Formed Strands - construction 1x19( 9/9/1 ) - Right Hand Lay
Wire Characteristics
|
Diameter
|
Flow Tube Bore*
|
Min. Pulley Diameter Inches**
|
Weight Lbs/ 1000ft Conventional
|
|
3/16”
|
0.196
|
12
|
85
|
|
7/32”
|
0.228
|
14
|
110
|
|
1/ 4”
|
0.263
|
16
|
150
|
|
5/16”
|
0.33
|
20
|
235
|
General Information
*Flow Tube Bore - the off tension diameter will be stated on the works test certificate. It is recommended that note be taken of this when first using the strand.
*Minimum Pulley Diameter - the figures shown above are our recommendations for reasonable fatigue life. The breaking loads being used should also be considered.
Nominal Breaking Loads
|
Diameter
|
Galvanised
|
316
|
GD31MO
|
|
3/16”
|
6170
|
4940
|
5060
|
|
7/32”
|
8370
|
6500
|
6110
|
|
1/ 4”
|
11200
|
8640
|
8700
|
|
5/16”
|
17550
|
13560
|
13470
|
|