Danum Well Services is approved and registered BS EN ISO 9001. Futhermore, all wirelines and strands are tested and certified by an independent laboratory as per DIN. 50049-3.1 b

V1000 Wireline Inhibitor

V1000 has been specially formulated for the purposes of inhibiting, sealing and lubricating Wirelines and logging cables.

It is produced from a blend of high quality esters enhanced with an additive package designed to give outstanding protection against such corrosive gases as hydrogen sulphide and carbon dioxide.

In addition to its excellent corrosion resistance, V1000 has a high viscosity index, a high flash point and is easy to apply.  

FIRST AID MEASURES

Inhalation- move the exposed person to fresh air at once. Get medical attention if any discomfort continues.
Ingestion- Never make unconscious person vomit or drink fluids! Rinse mouth thoroughly. Drink plenty of water. Get medical attention if any discomfort continues.
Skin contact- Remove affected person from source of contamination. Get medical attention if irritation persists after washing.
Eye contact- make sure to remove any contact lenses from the eyes before rinsing. Promptly wash eyes with plenty of water while lifting the eye lids. Continue to rinse at least for 15 minutes. Get medical attention if any discomfort continues.

FIRE FIGHTING MEASURES

This product is not flammable. Use fire extinguishing media appropriate for
surrounding materials.

ACCIDENTAL RELEASE MEASURES

Stop leak if possible without risk. Absorb in vermiculite, dry sand or earth and place
into containers. Flush area with plenty of water. do not contaminate
water sources or sewer.

HANDLING AND STORAGE

- Store at ambient temperature.
- Protect from water Store under Cover if possible.

EXPOSURE CONTROL/ PERSONAL PROTECTION

Ingredient Comments:
OES- Occupational Exposure Standard
Engineering measures:
Provide adequate general and local exhaust ventilation.
Eye Protection:
If risk of splashing, wear protective goggles or face shield.
Other protection:
Wear appropriate clothing to prevent any possibility of skin contact.
Hygiene measures:
DO NOT SMOKE IN WORK AREA! Wash at the end of each work shift and before eating, smoking and using the toilet. Wash promptly if skin becomes wet or contaminated. Promptly remove any clothing become contaminated.
Use appropriate skin cream to prevent drying of skin. When using, do not eat, drink or smoke.

PHYSICAL AND CHEMICAL PROPERTIES

Appearance: Liquid
Colour: Amber
Odour: Characteristic
Relative density: 0.920 Typical @ 20°C Flash Point (ºC): min. 290°C
Viscosity: 1,000 cSt at 40°C

STABILITY AND REACTIVITY

Stable under normal temperature conditions.
Avoid excessive heat for prolonged periods of time.
Fire creates: Carbon Dioxide (CO2) and Carbon Monoxide (CO)

TOXICOLOGICAL INFORMATION

Inhalation- may cause irritation for respiratory system. Ingestion- may cause discomfort if swallowed.
Skin Contact- may cause sensitisation by skin contact. Eye Contact- dust may cause transient irritation.

DISPOSAL METHODS

Dispose of waste and residues in accordance with local authority requirements.
REGULATORY INFORMATION

RISK PHRASES:

Not Classified

SAFETY PHRASES:

P13 Safety data sheet available for professional user on request.

UK REGULATORY REF.:

Health and Safety at Work Act 1974. EU DIRECTIVES:
System of specific information relating to Dangerous Preparations 2001/58/EC STATUATORY INSTRUMENTS:
Chemical (Hazard Information and Packaging for Supply) Reg. 2002 (CHIP3) APPROVED CODE OF PRACTCE:
Classification and Labelling of Substances and Preparations Dangerous for Supply.

GUIDANCE NOTES:

CHIP for everyone HSG(108). Workplace Exposure Limits EH40